23
manual ©eowave/Ircam 2003
Configuration of inputs 1 to 16 is the same for each input
6, 0 0 8 0 0 8 1 0 0 0 0 0 3 0 0 0 0 0 example of input 1
status ON, 7 resolution, zoom off, offset O, type CC, Channel 1, Gate 8,
Subsamp 0, Val1 1, Prm 1 0, Prm2 0
All parameters in 8 bit format on 2 bytes except for the offset in 14 bits on two 8
bits values (MSB/LSB)
Note: some parameters are coded on the same bit
1 0 0 subsampling
2 0 0 gate + resolution (gate + 128 for 10 bits, gate + 0 for 7 bits)
3 0 MIDI Channel
4 0 Type of controller +status ON/OFF (Type + 8 for ON, Type + 0 for OFF)
5 0 0 Value 1 (0-127)
6 0 0 Prm 1 (0-127)
7 0 0 Prm 2 (0-127)
8 0 0 Zooming (0-3) - (0 is max, 3 is off)
9 0 0 0 0 offset in 14 bits only the first 10 bits are used
A code which is directly sent to eo•body will be like:
240 0 32 57 64 127 0 8 0 0 15 0 0 4 0 0 2 0 1 0 3 0 1 0 4 0 0 0 1 0 0 0
2 0 0 0 3 0 0 0 0 0 8 0 0 8 1 0 0 0 0 0 3 0 0 0 0 0 0 0 8 0 0 8 2 0 0 0
0 0 3 0 0 0 0 0 0 0 8 0 0 8 3 0 0 0 0 0 3 0 0 0 0 0 0 0 8 0 0 8 4 0 0 0
0 0 3 0 0 0 0 0 0 0 8 0 0 8 5 0 0 0 0 0 3 0 0 0 0 0 0 0 8 0 0 8 6 0 0 0
0 0 3 0 0 0 0 0 0 0 8 0 0 8 7 0 0 0 0 0 3 0 0 0 0 0 0 0 8 0 0 8 8 0 0 0
0 0 3 0 0 0 0 0 0 0 8 0 0 8 9 0 0 0 0 0 3 0 0 0 0 0 0 0 8 0 0 8 10 0 0
0 0 0 3 0 0 0 0 0 0 0 8 0 0 8 11 0 0 0 0 0 3 0 0 0 0 0 0 0 8 0 0 8 12 0
0 0 0 0 3 0 0 0 0 0 0 0 8 0 0 8 13 0 0 0 0 0 3 0 0 0 0 0 0 0 8 0 0 8 14
0 0 0 0 0 3 0 0 0 0 0 0 0 8 0 0 8 15 0 0 0 0 0 3 0 0 0 0 0 0 0 8 0 0 8
0 1 0 0 0 0 3 0 0 0 0 0 247